SCLS263R December 1995 – October 2023 SN54AHCT74 , SN74AHCT74
PRODMIX
Refer to the PDF data sheet for device specific package drawings
PARAMETER | FROM (INPUT) | TO (OUTPUT) | LOAD CAPACITANCE | TA = 25°C | TA = –55°C TO 125°C | TA = –40°C TO 85°C | TA = –40°C TO 125°C | UNIT | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recommended | |||||||||||||
SN54AHCT74 | SN54AHCT74 | SN54AHCT74 | |||||||||||
MIN | TYP | MAX | MIN | MAX | MIN | MAX | MIN | MAX | |||||
fmax | CL = 15 pF | 100(1) | 160(1) | 90 | 80 | 80 | ns | ||||||
CL = 50pF | 80 | 140 | 65 | 65 | 65 | ||||||||
tPLH | PRE or CLR | Q or Q | CL = 15 pF | 7.6(1) | 10.4(1) | 1(1) | 12(1) | 1 | 12 | 1 | 12 | ns | |
tPHL | 7.6(1) | 10.4(1) | 1(1) | 12(1) | 1 | 12 | 1 | 12 | |||||
tPLH | CLK | Q or Q | CL = 15 pF | 5.8(1) | 7.8(1) | 1(1) | 9(1) | 1 | 9 | 1 | 9.0 | ns | |
tPHL | 5.8(1) | 7.8(1) | 1(1) | 9(1) | 1 | 9 | 1 | 9.0 | |||||
tPLH | PRE or CLR | Q or Q | CL = 50 pF | 8.1 | 11.4 | 1 | 13 | 1 | 13 | 1 | 13 | ns | |
tPHL | 8.1 | 11.4 | 1 | 13 | 1 | 13 | 1 | 13 | |||||
tPLH | CLK | Q or Q | CL = 50 pF | 6.3 | 8.8 | 1 | 10 | 1 | 10 | 1 | 10 | ns | |
tPHL | 6.3 | 8.8 | 1 | 10 | 1 | 10 | 1 | 10 |