SLLSEO9D March   2016  – October 2024 SN65DPHY440SS , SN75DPHY440SS

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics, Power Supply
    6. 5.6 Electrical Characteristics
    7. 5.7 Timing Requirements
    8. 5.8 Switching Characteristics
    9. 5.9 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 HS Receive Equalization
      2. 6.3.2 HS TX Edge Rate Control
      3. 6.3.3 TX Voltage Swing and Pre-Emphasis Control
      4. 6.3.4 Dynamic De-skew
    4. 6.4 Device Functional Modes
      1. 6.4.1 Shutdown Mode
      2. 6.4.2 LP Mode
      3. 6.4.3 ULPS Mode
      4. 6.4.4 HS Mode
    5. 6.5 Register Maps
      1. 6.5.1  BIT Access Tag Conventions
      2. 6.5.2  Standard CSR Registers (address = 0x000 - 0x07)
      3. 6.5.3  Standard CSR Register (address = 0x08)
      4. 6.5.4  Standard CSR Register (address = 0x09)
      5. 6.5.5  Standard CSR Register (address = 0x0A)
      6. 6.5.6  Standard CSR Register (address = 0x0B)
      7. 6.5.7  Standard CSR Register (address = 0x0D)
      8. 6.5.8  Standard CSR Register (address = 0x0E)
      9. 6.5.9  Standard CSR Register (address = 0x10) [reset = 0xFF]
      10. 6.5.10 Standard CSR Register (address = 0x11) [reset = 0xFF]
  8. Application and Implementation
    1. 7.1 Application Information,
    2. 7.2 Typical Application, CSI-2 Implementations
      1. 7.2.1 Design Requirements
      2. 7.2.2 Detailed Design Procedure
        1. 7.2.2.1 Reset Implementation
      3. 7.2.3 Application Curves
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  9. Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Typical Application, CSI-2 Implementations

The DPHY440 supports 4 CSI-2 DPHY lanes plus a clock. Unlike DSI, CSI-2 does not have a back channel path. Because of this, there is no requirement on lane ordering. Because there is no lane ordering requirement, there are more combinations which can be implemented. All possible combinations are supported by the DPHY440. For all CSI-2 implementations, the polarity must be maintained between the CSI-2 Source and CSI-2 Sink. The DPHY440 does not support polarity inversion.

SN65DPHY440SS SN75DPHY440SS CSI-2 Example: Typical SNx5DPHY440SS Placement in the SystemFigure 7-1 CSI-2 Example: Typical SNx5DPHY440SS Placement in the System
SN65DPHY440SS SN75DPHY440SS CSI-2 Two Lane ExampleFigure 7-2 CSI-2 Two Lane Example