SLIS128D November   2011  – April 2022 SN65HVDA100-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Description (continued)
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings (1) (1)
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Dissipation Ratings
    8. 7.8 Typical Characteristics
  8. Parameter Measurement Information
    1. 8.1 17
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  LIN (Local Interconnect Network) Bus
        1. 9.3.1.1 LIN Transmitter Characteristics
        2. 9.3.1.2 LIN Receiver Characteristics
          1. 9.3.1.2.1 Termination
      2. 9.3.2  TXD (Transmit Input / Output)
      3. 9.3.3  RXD (Receive Output)
      4. 9.3.4  VSUP (Supply Voltage)
      5. 9.3.5  GND (Ground)
      6. 9.3.6  EN (Enable Input)
      7. 9.3.7  NWake (High Voltage Wake Up Input)
      8. 9.3.8  INH (Inhibit Output)
      9. 9.3.9  TXD Dominant State Timeout
      10. 9.3.10 Thermal Shutdown
      11. 9.3.11 Bus Stuck Dominant System Fault: False Wake-Up Lockout
      12. 9.3.12 Undervoltage on VSUP
      13. 9.3.13 Unpowered Device Does Not Affect the LIN Bus
    4. 9.4 Device Functional Modes
      1. 9.4.1 Operating States
      2. 9.4.2 Normal Mode
      3. 9.4.3 Sleep Mode
      4. 9.4.4 Wake-Up Events
        1. 9.4.4.1 Wake-Up Request (RXD)
        2. 9.4.4.2 Wake-Up Source Recognition (TXD)
      5. 9.4.5 Standby Mode
      6. 9.4.6 Mode Transitions
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 Support Resources
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

LIN (Local Interconnect Network) Bus

This I/O pin is the single-wire LIN bus transmitter and receiver. The LIN pin can survive excessive DC and transient voltages. There are no reverse currents from the LIN to supply (VSUP), even in the event of a ground shift or loss of supply (VSUP).