SCLS525C July 2003 – April 2024 SN74AHC125-Q1
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
VALUE | UNIT | |||
---|---|---|---|---|
V(ESD) | Electrostatic discharge | Human body model (HBM), per AEC Q100-002 HBM ESD Classification Level 2(1) | ±2000 | V |
Charged device model (CDM), per AEC Q100-011 CDM ESD Classification Level C4B | ±1000 | |||
V(ESD) | Electrostatic discharge | Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(2) | ±2000 | V |
Charged-device model (CDM), per ANSI/ESDA/JEDEC JS-002(3) | ±1000 |