SCLS256O December 1995 – February 2024 SN54AHC125 , SN74AHC125
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
PARAMETER | FROM (INPUT) |
TO (OUTPUT) |
TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|---|---|
tPHL, tPLH | A | Y | CL = 15 pF | TA = 25°C | 5.6(1) | 8(1) | ns | |
TA = –55°C to 125°C (SN54AHC125) | 1(1) | 9.5(1) | ||||||
TA = –40°C to 85°C (SN74AHC125) | 1 | 9.5 | ||||||
TA = –40°C to 125°C (recommended SN74AHC125) |
1 | 9.5 | ||||||
tPZL, tPZH | OE | Y | CL = 15 pF | TA = 25°C | 5.4(1) | 8(1) | ns | |
TA = –55°C to 125°C (SN54AHC125) | 1(1) | 9.5(1) | ||||||
TA = –40°C to 85°C (SN74AHC125) | 9.5 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) |
9.5 | |||||||
tPLZ, tPHZ | OE | Y | CL = 15 pF | TA = 25°C | 7.0(1) | 9.7(1) | ns | |
TA = –55°C to 125°C (SN54AHC125) | 1(1) | 11.5(1) | ||||||
TA = –40°C to 85°C (SN74AHC125) | 1(1) | 11.5(1) | ||||||
TA = –40°C to 125°C (recommended SN74AHC125) |
1(1) | 11.5(1) | ||||||
tPHL, tPLH | A | Y | CL = 50 pF | TA = 25°C | 8.1 | 11.5 | ns | |
TA = –55°C to 125°C (SN54AHC125) | 1 | 13 | ||||||
TA = –40°C to 85°C (SN74AHC125) | 1 | 13 | ||||||
TA = –40°C to 125°C (recommended SN74AHC125) |
1 | 13 | ||||||
tPZL, tPZH | OE | Y | CL = 50 pF | TA = 25°C | 7.9 | 11.5 | ns | |
TA = –55°C to 125°C (SN54AHC125) | 1 | 13 | ||||||
TA = –40°C to 85°C (SN74AHC125) | 1 | 13 | ||||||
TA = –40°C to 125°C (recommended SN74AHC125) |
1 | 13 | ||||||
tPLZ, tPHZ | OE | Y | CL = 50 pF | TA = 25°C | 9.5 | 13.2 | ns | |
TA = –55°C to 125°C (SN54AHC125) | 1 | 15 | ||||||
TA = –40°C to 85°C (SN74AHC125) | 1 | 15 | ||||||
TA = –40°C to 125°C (recommended SN74AHC125) |
1 | 15 | ||||||
tsk(o) | OE | Y | CL = 50 pF | TA = 25°C | 1.5(2) | ns | ||
TA = –40°C to 85°C (SN74AHC125) | 1.5 |