SCLS256O December 1995 – February 2024 SN54AHC125 , SN74AHC125
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |||
---|---|---|---|---|---|---|---|---|
VOH | IOH = –50 µA | VCC = 2 V | TA = 25°C | 1.9 | 2 | V | ||
TA = –55°C to 125°C (SN54AHC125) | 1.9 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 1.9 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 1.9 | |||||||
VCC = 3 V | TA = 25°C | 2.9 | 3 | |||||
TA = –55°C to 125°C (SN54AHC125) | 2.9 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 2.9 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 2.9 | |||||||
VCC = 4.5 V | TA = 25°C | 4.4 | 4.5 | |||||
TA = –55°C to 125°C (SN54AHC125) | 4.4 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 4.4 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 4.4 | |||||||
IOH = –4 mA and VCC = 3 V | TA = 25°C | 2.58 | ||||||
TA = –55°C to 125°C (SN54AHC125) | 2.48 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 2.48 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 2.48 | |||||||
IOH = –8 mA and VCC = 4.5 V | TA = 25°C | 3.94 | ||||||
TA = –55°C to 125°C (SN54AHC125) | 3.8 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 3.8 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 3.8 | |||||||
VOL | IOL = 50 µA | VCC = 2 V | TA = 25°C | 0.1 | V | |||
TA = –55°C to 125°C (SN54AHC125) | 0.1 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 0.1 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 0.1 | |||||||
VCC = 3 V | TA = 25°C | 0.1 | ||||||
TA = –55°C to 125°C (SN54AHC125) | 0.1 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 0.1 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 0.1 | |||||||
VCC = 4.5 V | TA = 25°C | 0.1 | ||||||
TA = –55°C to 125°C (SN54AHC125) | 0.1 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 0.1 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 0.1 | |||||||
IOH = 4 mA and VCC = 3 V | TA = 25°C | 0.36 | ||||||
TA = –55°C to 125°C (SN54AHC125) | 0.5 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 0.44 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 0.5 | |||||||
IOH = 8 mA and VCC = 4.5 V | TA = 25°C | 0.36 | ||||||
TA = –55°C to 125°C (SN54AHC125) | 0.5 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 0.44 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 0.5 | |||||||
II | VI = 5.5 V or GND and VCC = 0 V to 5.5 V | TA = 25°C | ±0.1 | µA | ||||
TA = –55°C to 125°C (SN54AHC125) | ±1(1) | |||||||
TA = –40°C to 85°C (SN74AHC125) | ±1 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | ±1 | |||||||
IOZ | VO = VCC or GND and VCC = 5.5 V | TA = 25°C | ±0.25 | µA | ||||
TA = –55°C to 125°C (SN54AHC125) | ±2.5 | |||||||
TA = –40°C to 85°C (SN74AHC125) | ±2.5 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | ±2.5 | |||||||
ICC | VI = VCC or GND, IO = 0, and VCC = 5.5 V | TA = 25°C | 4 | µA | ||||
TA = –55°C to 125°C (SN54AHC125) | 40 | |||||||
TA = –40°C to 85°C (SN74AHC125) | 40 | |||||||
TA = –40°C to 125°C (recommended SN74AHC125) | 40 | |||||||
Ci | VI = VCC or GND and VCC = 5 V | TA = 25°C | 4 | 10 | pF | |||
TA = –40°C to 85°C (SN74AHC125) | 10 |