SCLS511A June   2003  – February 2024 SN74AHC4066

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Thermal Information
    4. 5.4  Recommended Operating Conditions
    5. 5.5  Electrical Characteristics
    6. 5.6  Switching Characteristics
    7. 5.7  Switching Characteristics
    8. 5.8  Switching Characteristics
    9. 5.9  Analog Switching Characteristics
    10. 5.10 Operating Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 Documentation Support
      1. 8.1.1 Related Documentation
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • D|14
  • RGY|14
  • DB|14
  • DGV|14
  • PW|14
  • N|14
  • NS|14
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

TA = –40 to +85 °C unless otherwise specified.
PARAMETER TEST CONDITIONS VCC TA = 25°C MIN MAX UNIT
MIN TYP MAX
ron On-state switch resistance IT = –1mA, VI = 0 to VCC,
VC = VIH (see Figure 6-1)
2.3V 38 180 225 Ω
3V 29 150 190
4.5V 21 75 100
ron(p) Peak on-state resistance IT = –1mA
VI = VCC to GND
VC = VIH
2.3V 143 500 600 Ω
3V 57 180 225
4.5V 31 100 125
Δron Difference in on-state resistance between switches IT = –1mA
VI = VCC to GND
VC = VIH
2.3V

6

30 40 Ω
3V

3

20 30
4.5V 2 15 20
IIH 
IIL
Control input current VC = 0 or VCC 5.5 ±0.1 ±1 µA
Is(off) Off-state switch leakage current VI = VCC and
VO = GND, or
VI = GND and
VO = VCC,
VC = VIL
(see Figure 6-2)
5.5V ±0.1 ±1 µA
Is(on) On-state switch leakage current VI = VCC or GND,
VC = VIH
(see Figure 6-3)
5.5V ±0.1 ±1 µA
ICC Supply current VI = VCC or GND 5.5V 20 µA
CiC Control input capacitance 1.5 pF
CiO Switch input/output capacitance 5.5 pF
CF Feed-through capacitance 0.5 pF