SCLS246T October 1995 – October 2023 SN54AHCT14 , SN74AHCT14
PRODUCTION DATA
PARAMETER | FROM (INPUT) |
TO (OUTPUT) |
LOAD CAPACITANCE |
TA = 25°C | SN54AHCT14 | SN74AHCT14 | UNIT | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
MIN | TYP | MAX | MIN | MAX | MIN | MAX | |||||
tPLH | A | Y | CL = 15 pF | 4(1) | 7(1) | 1(1) | 8(1) | 1 | 8 | ns | |
tPHL | 4(1) | 7(1) | 1(1) | 8(1) | 1 | 8 | |||||
tPLH | A | Y | CL = 50 pF | 5.5 | 8 | 1 | 9 | 1 | 9 | ns | |
tPHL | 5.5 | 8 | 1 | 9 | 1 | 9 |