SCES590E JULY 2004 – March 2018 SN74AUP1G06
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
PARAMETER | TEST CONDITIONS | VCC | MIN | TYP | MAX | UNIT | |||
---|---|---|---|---|---|---|---|---|---|
VOL | Low-level output voltage | IOL = 20 µA | TA = 25°C | 0.8 V to 3.6 V | 0.1 | V | |||
TA = –40°C to +85°C | 0.1 | ||||||||
IOL = 1.1 mA | TA = 25°C | 1.1 V | 0.3 × VCC | ||||||
TA = –40°C to +85°C | 0.3 × VCC | ||||||||
IOL = 1.7 mA | TA = 25°C | 1.4 V | 0.31 | ||||||
TA = –40°C to +85°C | 0.37 | ||||||||
IOL = 1.9 mA | TA = 25°C | 1.65 V | 0.31 | ||||||
TA = –40°C to +85°C | 0.35 | ||||||||
IOL = 2.3 mA | TA = 25°C | 2.3 V | 0.31 | ||||||
TA = –40°C to +85°C | 0.33 | ||||||||
IOL = 3.1 mA | TA = 25°C | 0.44 | |||||||
TA = –40°C to +85°C | 0.45 | ||||||||
IOL = 2.7 mA | TA = 25°C | 3 V | 0.31 | ||||||
TA = –40°C to +85°C | 0.33 | ||||||||
IOL = 4 mA | TA = 25°C | 0.44 | |||||||
TA = –40°C to +85°C | 0.45 | ||||||||
II | Inflection point current | A input:
VI = GND to 3.6 V |
TA = 25°C | 0 V to 3.6 V | 0.1 | µA | |||
TA = –40°C to +85°C | 0.5 | ||||||||
Ioff | Off-state current | VI or VO = 0 V to 3.6 V | TA = 25°C | 0 V | 0.2 | µA | |||
TA = –40°C to +85°C | 0.6 | ||||||||
ΔIoff | Off-state current change | VI or VO = 0 V to 3.6 V | TA = 25°C | 0 V to 0.2 V | 0.2 | µA | |||
TA = –40°C to +85°C | 0.6 | ||||||||
ICC | Supply current | VI = GND or VCC to 3.6 V
IO = 0 |
TA = 25°C | 0.8 V to 3.6 V | 0.5 | µA | |||
TA = –40°C to +85°C | 0.9 | ||||||||
ΔICC | Supply current change | VI = VCC – 0.6 V
IO = 0 |
TA = 25°C | 3.3 V | 40 | µA | |||
TA = –40°C to +85°C | 50 | ||||||||
Ci | Input capacitance | VI = VCC or GND, TA = 25°C | 0 V | 1.5 | pF | ||||
3.6 V | 1.7 | ||||||||
Co | Output capacitance | VO = GND, TA = 25°C | 0 V | 1.7 | pF |