Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP(1) MAX UNIT
VIK VCC = 3 V, II = –18 mA –1.2 V
II VCC = 3.6 V, VI = VCC or GND ±1 μA
Ioff VCC = 0, VI or VO = 0 to 3.6 V 15 μA
ICC VCC = 3.6 V, IO = 0, VI = VCC or GND 10 μA
ΔICC(2) Control inputs VCC = 3.6 V, one input at 3 V, other inputs at VCC or GND 300 μA
Ci Control inputs VI = 3 V or 0 3 pF
Cio(OFF) A port VO = 3 V or 0, OE = VCC 10.5 pF
B port 5.5
ron(3) VCC = 2.3 V,
TYP at VCC = 2.5 V
VI = 0 II = 64 mA 5 8
II = 24 mA 5 8
VI = 1.7 V II = 15 mA 27 40
VCC = 3 V VI = 0 II = 64 mA 5 7
II = 24 mA 5 7
VI = 2.4 V II = 15 mA 10 15
All typical values are at VCC = 3.3 V (unless otherwise noted), TA = 25°C.
This is the increase in supply current for each input that is at the specified voltage level, rather than VCC or GND.
Measured by the voltage drop between the A and the B terminals at the indicated current through the switch. On-state resistance is determined by the lower of the voltages of the two (A or B) terminals.