SCLS824 August   2020  – MONTH  SN74HCS16507-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
    1.     4
    2.     5
  4. Revision History
  5. Pin Configuration and Functions
    1.     8
    2.     9
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Characteristics
    7. 6.7 Switching Characteristics
    8. 6.8 Operating Characteristics
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Open-Drain CMOS Outputs
      2. 8.3.2 Balanced CMOS Push-Pull Outputs
      3. 8.3.3 Clamp Diode Structure
      4. 8.3.4 Latching Logic
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Reference
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
        1. 9.2.1.1 Power Considerations
        2. 9.2.1.2 Input Considerations
        3. 9.2.1.3 Output Considerations
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Device Functional Modes

The Operating Mode Table and the Output Function Table list the functional modes of the SN74HCS16507-Q1.

Table 8-1 Operating Mode Table
INPUTS(1) FUNCTION
SH/LD CLK CLK INH
L X X Parallel load
H H X No change
H X H No change
H L Shift(2)
H L Shift(2)
H = High Voltage Level, L = Low Voltage Level, X = Don't Care, ↑ = Low to High transition
Shift : Content of each internal register shifts towards serial output QH. Data at SER is shifted into the first register.
Table 8-2 Output Function Table
INTERNAL REGISTERS(1)(2) OUTPUTS(2)
A — G H Q Q
X L L Z
X H Z L
Internal registers refer to the shift registers inside the device. These values are set by either loading data from the parallel inputs, or by clocking data in from the serial input.
H = High Voltage Level, L = Low Voltage Level, X = Don't Care, Z = High Impedance