SCLS922 may   2023 SN74LV2T74

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  Timing Characteristics 1.8-V VCC
    7. 6.7  Timing Characteristics 2.5-V VCC
    8. 6.8  Timing Characteristics 3.3-V VCC
    9. 6.9  Timing Characteristics 5-V VCC
    10. 6.10 Switching Characteristics 1.8-V VCC
    11. 6.11 Switching Characteristics 2.5-V VCC
    12. 6.12 Switching Characteristics 3.3-V VCC
    13. 6.13 Switching Characteristics 5-V VCC
    14. 6.14 Noise Characteristics
    15. 6.15 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Balanced CMOS 3-State Outputs
      2. 8.3.2 Clamp Diode Structure
      3. 8.3.3 LVxT Enhanced Input Voltage
        1. 8.3.3.1 Down Translation
        2. 8.3.3.2 Up Translation
      4. 8.3.4 Wettable Flanks
    4. 8.4 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
        1. 9.2.1.1 Input Considerations
        2. 9.2.1.2 Output Considerations
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  11. 10Power Supply Recommendations
  12. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Support Resources
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 Glossary
  13. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Timing Characteristics 2.5-V VCC

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER DESCRIPTION CONDITION TA = 25°C -40°C to 125°C UNIT
MIN MAX MIN MAX
tW Pulse duration PRE or CLR LOW 7 8 nS
tW Pulse duration CLK 7 8 nS
tSU Setup time before CLK↑ Data 7 8 nS
tSU Setup time before CLK↑ PRE or CLR Inactive 6 6 nS
tH Hold time, data after CLK↑ 0.5 0.5 nS