Table 8-1 lists the functional modes of the SN74LV393B-EP.
Table 8-1 Operating Mode TableINPUTS | FUNCTION(1) |
---|
CLK | CLR |
---|
↑ | L | No change |
↓ | L | Advance to next stage |
X | H | All outputs L |
(1) H = High Voltage Level, L = Low Voltage Level, X = Do Not Care, ↑ = Low to High transition