SLLS145D October   1990  – October 2023 SN65175 , SN75175

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Dissipation Rating
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
  10. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • NS|16
  • N|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended ranges of common-mode input voltage, supply voltage and operating free-air temperature
PARAMETER TEST CONDITIONS MIN TYP (1) MAX UNIT
VIT+ Positive-going input threshold voltage VO = 2.7 V, IO = –0.4 mA 0.2 V
VIT- Negative-going input threshold voltage VO = 0.5 V, IO = 16 mA –0.2 (2) V
Vhys Hysteresis voltage (VIT+ - VIT-) See Figure 5-1 50 mV
VIK Enable-input clamp voltage II = –18 mA -1.5 V
VOH High-level output voltage VID = 200 mV, IOH = –400 µA, See Figure 6-1 2.7 V
VOL Low-level output voltage VID = –200 mV, See Figure 6-1 IOL = 8 mA 0.45 V
IOL = 16 mA 0.5
IOZ High-impedance-state output current VO = 0.4 V to 2.4 V ±20 µA
II Line input current Other input at 0 V, See (4) VI = 12 V 1 mA
VI = –7 V -0.8
IIH High-level enable-input current VIH = 2.7 V 20 µA
IIL Low-level enable-input current VIL = 0.4 V -100 µA
ri Input resistance 12
IOS Short-circuit output current (3) -15 -85 mA
ICC Supply current Outputs disabled 70 mA
All typical values are at VCC = 5 V, TA = 25°C.
The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold voltage levels only.
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
Refer to ANSI Standards EIA/TIA-422-B, RS-423-B, and RS-485 for exact conditions.