4 Revision History
Changes from * Revision (November 2009) to A Revision
-
Changed the data sheet to the new TI standard format Go
-
Changed Feature From: Temperature Range: 0..85°C To: Temperature Range: –40 to 85°CGo
-
Changed the Description text From: "extended operational temperature range from 0°C to 85°C." To: "extended operational temperature range from –40°C to 85°C."Go
-
Added the Handling Ratings tableGo
-
Changed the Operating free-air temperature MIN value in the ROC table From: 0 To –40Go
-
Added the Thermal Information tableGo