over operating free-air temperature range (unless otherwise noted)(1)
|
|
MIN |
MAX |
UNIT |
VCC |
Supply voltage range (see Note 1) |
−0.3 |
6 |
V |
|
Voltage range at
any bus input (DC) |
−10 |
15 |
V |
|
Voltage range at any bus input |
(transient pulse
through 100 Ω, see Figure 6-5) |
−30 |
30 |
V |
VI
|
Voltage input
range at G and G |
−0.5 |
VCC + 0.5 |
V |
IO
|
Receiver output
current |
|
±10 |
mA |
|
Continuous power
dissipation |
See Power Dissipation Rating Table |
|
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to GND, and are steady-state (unless otherwise specified).