SLASEE8B November 2016 – February 2019 TAS2559
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
Sticky register used to indicate the source of an interrupt trigger. Register is cleared once read.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | Reserved | Reserved | Reserved | INT_CLK1 | INT_CLK2 | Reserved | Reserved |
R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | Reserved | R | 0h | Reserved |
6 | Reserved | R | 0h | Reserved |
5 | Reserved | R | 0h | Reserved |
4 | Reserved | R | 0h | Reserved |
3 | INT_CLK1 | R | 0h | Sticky bit indicating that clock error 1 condition
0 = did not occurred since last read 1 = occurred since last read |
2 | INT_CLK2 | R | 0h | Sticky bit indicating that the clock error 2 condition
0 = did not occurred since last read 1 = occurred since last read |
1 | Reserved | R | 0h | Reserved |
0 | Reserved | R | 0h | Reserved |