SLOSE86B july 2022 – july 2023 TAS2781
PRODUCTION DATA
The output slew rate can be programmed using bits EDGE_CTRL[1:0] from register in .
By default, if PVDDH supply is below 20 V the output slew rate will be at a fast rate, dependant on supply and load. If PVDDH goes above 20 V the slew rate will be automatically change to a slower rate.
Optionally, to improve EMI performance, user can set the slew rate to a slower rate for the entire range of PVDDH supply by setting the bits EDGE_CTRL[1:0] to 2'b11.