SLOSE86B july 2022 – july 2023 TAS2781
PRODUCTION DATA
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | IR_BOPM | R | 0h | Interrupt due to BOP mute 0h = No interrupt 1h = Interrupt |
6 | IR_BOPIH | R | 0h | Interrupt due to BOP infinite hold 0h = No interrupt 1h = Interrupt |
5 | IR_LIMMA | R | 0h | Interrupt due to limiter max
attenuation 0h = No interrupt 1h = Interrupt |
4 | IR_PBIP | R | 0h | Interrupt due to PVDDH below limiter
inflection point 0h = No interrupt 1h = Interrupt |
3 | IR_LIMA | R | 0h | Interrupt due to limiter active 0h = No interrupt 1h = Interrupt |
2 | IR_TDMCE | R | 0h | Interrupt due to TDM clock error 0h = No interrupt 1h = Interrupt |
1 | IR_OC | R | 0h | Interrupt due to over current 0h = No interrupt 1h = Interrupt |
0 | IR_OT | R | 0h | Interrupt due to over temperature 0h = No interrupt 1h = Interrupt |