SLAS965D September 2013 – October 2018 TAS5766M , TAS5768M
PRODUCTION DATA.
A master can write to any TAS576xM registers using single or multiple accesses. The master sends a TAS576xM slave address with a write bit, a register address with auto-increment bit, and the data. If auto-increment is enabled, the address is that of the starting register, followed by the data to be transferred. When the data is received properly, the index register is incremented by 1 automatically. When the index register reaches 0x7F, the next value is 0x0. The following table shows the write operation.
Transmitter | M | M | M | S | M | S | M | S | M | S | S | M | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Data Type | St | Slave addr | W | ACK | inc | reg addr | ACK | Write data1 | ACK | Write data2 | ACK | ACK | Sp | |