SLOSE95A december 2022 – september 2023 TAS6424R-Q1
PRODUCTION DATA
The Warnings register is shown in Figure 9-30 and described in Table 9-26.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED | VDD POR | OTW | OTW CH1 | OTW CH2 | OTW CH3 | OTW CH4 | |
R-0 | R-0 | R-0 | R-0 | R-0 | R-0 |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7-6 | RESERVED | R | 0 | RESERVED |
5 | VDD POR | R | 0 | 0: No VDD POR has occurred 1 VDD POR occurred |
4 | OTW | R | 0 | 0: No global overtemperature warning 1: Global overtemperature warning |
3 | OTW CH1 | R | 0 | 0: No overtemperature warning on channel 1 1: Overtemperature warning on channel 1 |
2 | OTW CH2 | R | 0 | 0: No overtemperature warning on channel 2 1: Overtemperature warning on channel 2 |
1 | OTW CH3 | R | 0 | 0: No overtemperature warning on channel 3 1: Overtemperature warning on channel 3 |
0 | OTW CH4 | R | 0 | 0: No overtemperature warning on channel 4 1: Overtemperature warning on channel 4 |