SLOSE95A december 2022 – september 2023 TAS6424R-Q1
PRODUCTION DATA
The operating modes and faults are listed in the following tables.
STATE NAME | OUTPUT FETS | OSCILLATOR | I2C |
---|---|---|---|
STANDBY | Hi-Z | Stopped | Active |
Hi-Z | Hi-Z | Active | Active |
MUTE | Switching at 50% | Active | Active |
PLAY | Switching with audio | Active | Active |
FAULT/ EVENT | FAULT/EVENT CATEGORY | MONITORING MODES | REPORTING METHOD | ACTION RESULT |
---|---|---|---|---|
POR | Voltage fault | All | I2C + WARN pin | Standby |
VBAT UV | Hi-Z, mute, normal | I2C + FAULT pin | Hi-Z | |
PVDD UV | ||||
VBAT or PVDD OV | ||||
OTW | Thermal warning | Hi-Z, mute, normal | I2C + WARN pin | None |
OTSD | Thermal shutdown | Hi-Z, mute, normal | I2C + FAULT pin | Hi-Z |
FAULT/ EVENT | FAULT/EVENT CATEGORY | MONITORING MODES | REPORTING METHOD | ACTION TYPE |
---|---|---|---|---|
Clipping | Warning | Mute and play | I2C + WARNor FAULT pin | None |
Overcurrent limiting | Protection | I2C + WARN pin | Current limit | |
Overcurrent fault | Output channel fault | I2C + FAULT pin | Hi-Z | |
DC detect |