SLLSFD1E January   2021  – March 2023 TCAN1043A-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  ESD Ratings - IEC Specifications
    4. 6.4  Recommended Operating Conditions
    5. 6.5  Thermal Information
    6. 6.6  Power Dissipation Ratings
    7. 6.7  Power Supply Characteristics
    8. 6.8  Electrical Characteristics
    9. 6.9  Timing Requirements
    10. 6.10 Switching Characteristics
    11. 6.11 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Supply Pins
        1. 8.3.1.1 VSUP Pin
        2. 8.3.1.2 VCC Pin
        3. 8.3.1.3 VIO Pin
      2. 8.3.2 Digital Inputs and Outputs
        1. 8.3.2.1 TXD Pin
        2. 8.3.2.2 RXD Pin
        3. 8.3.2.3 nFAULT Pin
        4. 8.3.2.4 EN Pin
        5. 8.3.2.5 nSTB Pin
      3. 8.3.3 GND
      4. 8.3.4 INH Pin
      5. 8.3.5 WAKE Pin
      6. 8.3.6 CAN Bus Pins
      7. 8.3.7 Faults
        1. 8.3.7.1 Internal and External Fault Indicators
          1. 8.3.7.1.1 Power-Up (PWRON Flag)
          2. 8.3.7.1.2 Wake-Up Request (WAKERQ Flag)
          3. 8.3.7.1.3 Undervoltage Faults
            1. 8.3.7.1.3.1 Undervoltage on VSUP
            2. 8.3.7.1.3.2 Undervoltage on VCC
            3. 8.3.7.1.3.3 Undervoltage on VIO
          4. 8.3.7.1.4 CAN Bus Fault (CBF Flag)
          5. 8.3.7.1.5 TXD Clamped Low (TXDCLP Flag)
          6. 8.3.7.1.6 TXD Dominant State Timeout (TXDDTO Flag)
          7. 8.3.7.1.7 TXD Shorted to RXD Fault (TXDRXD Flag)
          8. 8.3.7.1.8 CAN Bus Dominant Fault (CANDOM Flag)
      8. 8.3.8 Local Faults
        1. 8.3.8.1 TXD Clamped Low (TXDCLP)
        2. 8.3.8.2 TXD Dominant Timeout (TXD DTO)
        3. 8.3.8.3 Thermal Shutdown (TSD)
        4. 8.3.8.4 Undervoltage Lockout (UVLO)
        5. 8.3.8.5 Unpowered Devices
        6. 8.3.8.6 Floating Terminals
        7. 8.3.8.7 CAN Bus Short-Circuit Current Limiting
    4. 8.4 Device Functional Modes
      1. 8.4.1 Operating Mode Description
        1. 8.4.1.1 Normal Mode
        2. 8.4.1.2 Silent Mode
        3. 8.4.1.3 Standby Mode
        4. 8.4.1.4 Go-To-Sleep Mode
        5. 8.4.1.5 Sleep Mode
          1. 8.4.1.5.1 Remote Wake Request via Wake-Up Pattern (WUP)
          2. 8.4.1.5.2 Local Wake-Up (LWU) via WAKE Input Terminal
      2. 8.4.2 CAN Transceiver
        1. 8.4.2.1 CAN Transceiver Operation
          1. 8.4.2.1.1 CAN Transceiver Modes
            1. 8.4.2.1.1.1 CAN Off Mode
            2. 8.4.2.1.1.2 CAN Autonomous: Inactive and Active
            3. 8.4.2.1.1.3 CAN Active
          2. 8.4.2.1.2 Driver and Receiver Function Tables
          3. 8.4.2.1.3 CAN Bus States
  9. Application Information Disclaimer
    1. 9.1 Application Information
      1. 9.1.1 Typical Application
      2. 9.1.2 Design Requirements
        1. 9.1.2.1 Bus Loading, Length and Number of Nodes
      3. 9.1.3 Detailed Design Procedure
        1. 9.1.3.1 CAN Termination
    2. 9.2 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Overview

The TCAN1043A-Q1 is a high-speed Controller Area Network (CAN) transceiver that meets the physical layer requirements of the ISO 11898-2:2016 high-speed CAN specification. The TCAN1043A-Q1 supports both classical CAN and CAN FD networks up to 8 megabits per second (Mbps).

The transceiver has three separate supply inputs, VSUP, VCC, and VIO. By using VIO, the TCAN1043A-Q1 can interface directly to a 1.8 V, 2.5 V, 3.3 V, or 5 V controller without the need for a level shifter. The TCAN1043A-Q1 allows for system-level reductions in battery current consumption by selectively enabling the various power supplies that may be present in the system via the INH output pin. This enables a low-current sleep state in which power is gated to all system components except for the TCAN1043A-Q1, which remains in a low-power state while monitoring the CAN bus. When a wake-up pattern is detected on the bus or when a local wake up is requested via the WAKE input, the device initiates node start-up by driving INH high.

The TCAN1043A-Q1 includes many protection and diagnostic features including undervoltage detection, CAN bus fault detection, SWE timer, battery connection detection, thermal shutdown (TSD), driver dominant timeout (TXD DTO), and bus fault protection up to ±58 V.