SLLSFE3 December 2021 TCAN1164-Q1
PRODUCTION DATA
Block | Power Off | Reset | Fail-safe | Normal | Standby | Silent |
---|---|---|---|---|---|---|
VCCOUT | Off | On | Off | On | On | On |
Low Power CAN RX | Off | Off | Fault determines | Off | Active | Off |
CAN Transmitter | Off | CAN Autonomous | Off | CAN Active | CAN Autonomous | Off |
CAN Receiver | Off | CAN Autonomous | Off | CAN Active | CAN Autonomous | Active |
RXD | High impedance | VCCOUT | VCCOUT | Mirrors Bus State | Entrance Dependent | Mirrors Bus State |
Watchdog | Off | Off | Off | Active | Active | Active |
SPI | Disabled | Disabled | Fault determines | Active | Active | Active |