SLLSFX3A October 2024 – October 2024 TCAN844-Q1
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
ICC | Supply current normal mode |
Dominant |
TXD = 0V, RL = 60Ω, CL = open | 44 | 70 | mA | |
Supply current normal mode |
Dominant |
TXD = 0V, RL = 50Ω, CL = open | 48 | 80 | mA | ||
Supply current normal mode |
Recessive | TXD = VCC, RL = 50Ω, CL = open, RCM = open | 5.6 | 10 | mA | ||
Supply current normal mode |
Dominant with bus fault | TXD = 0V, CANH = CANL = ±25V, RL = open, CL = open | 130 | mA | |||
Supply current standby mode |
TCAN844V | TXD = VIO, RL = 50Ω, CL = open | 5 | µA | |||
Supply current standby mode | TCAN844 | TXD = VCC, RL = 50Ω, CL = open | 30 | µA | |||
IIO | I/O supply current normal mode |
Dominant | RXD floating, TXD = 0V | 135 | 400 | µA | |
I/O supply current normal mode | Recessive | RXD floating, TXD = VIO | 28 | 150 | µA | ||
I/O supply current standby mode | RXD floating, TXD = VIO | 20 | 28 | µA | |||
UVVCC | Rising under voltage detection on VCC for protected mode | 4.2 | 4.6 | V | |||
UVVCC | Falling under voltage detection on VCC for protected mode | 3.5 | 4 | 4.5 | V | ||
UVVIO | Rising under voltage detection on VIO | 2.5 | 2.9 | V | |||
UVVIO | Falling under voltage detection on VIO | 2.1 | 2.4 | V | |||
TSD | Thermal shutdown temperature | 165 | 180 | 195 | |||
TSD_HYS | Thermal shutdown hysteresis | 10 |