SPRS996F March 2017 – February 2019 TDA2P-ACD
PRODUCTION DATA.
This section describes the Unused/Reserved balls connection requirements.
NOTE
he following balls are reserved: B28 / F6 / A27
These balls must be left unconnected.
NOTE
All unused power supply balls must be supplied with the voltages specified in the Section 5.4, Recommended Operating Conditions, unless alternative tie-off options are included in Section 4.3, Signal Descriptions.
Balls | Connection Requirements |
---|---|
AB16 / AC19 / D20 / AB19 / AC20 / AB21 / AB20 / U27 / AH25 / AC27 / AB27 / W28 / D28 / F27 / J27 / L28 | These balls must be connected to GND through an external pull resistor if unused |
E20 / D21 / D24 / C19 / C20 / U28 / F16 / AG25 / AC28 / AB28 / W27 / D27 / F28 / J28 / L27 / F15 / C24 | These balls must be connected to the corresponding power supply through an external pull resistor if unused |
G14 (vpp) | This ball must be left unconnected if unused. |
NOTE
All other unused signal balls with a Pad Configuration Register can be left unconnected with their internal pullup or pulldown resistor enabled.
NOTE
All other unused signal balls without Pad Configuration Register can be left unconnected.