SLLSFU3 October 2023 THVD1400V
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
Driver | |||||||
tr, tf | Differential output rise/fall time | RL = 54 Ω, CL = 50 pF See Figure 6-3 |
VCC = 3 to 3.6 V, Typical at 3.3 V | 6 | 15 | ns | |
VCC = 4.5 to 5.5 V, Typical at 5 V | 6 | 15 | ns | ||||
tPHL, tPLH | Propagation delay | VCC = 3 to 3.6 V, Typical at 3.3 V | 25 | 50 | ns | ||
VCC = 4.5 to 5.5 V, Typical at 5 V | 20 | 40 | ns | ||||
tSK(P) | Pulse skew, |tPHL – tPLH| | VCC = 3 to 3.6 V, Typical at 3.3 V | 1 | 6 | ns | ||
VCC = 4.5 to 5.5 V, Typical at 5 V | 1 | 6 | ns | ||||
tPHZ, tPLZ | Disable time | RE = X | See Figure 6-4 and Figure 6-5 | 25 | 50 | ns | |
tPZH, tPZL | Enable time | RE = 0 V | 30 | 70 | ns | ||
RE = VIO , VIO = 1.65 V to 2.75 V | 6 | 13 | μs | ||||
RE = VIO , VIO = 3 V to 5.5 V | 6 | 13 | μs | ||||
Receiver | |||||||
tr, tf | Output rise/fall time | CL = 15 pF | See Figure 6-6 | 5 | 10 | ns | |
tPHL, tPLH | Propagation delay | CL = 15 pF | 30 | 90 | ns | ||
tSK(P) | Pulse skew, |tPHL – tPLH| | CL = 15 pF, VIO < 2.25 V | 6 | ns | |||
tSK(P) | Pulse skew, |tPHL – tPLH| | CL = 15 pF, VIO ≥ 2.25 V | 8 | ns | |||
tPHZ, tPLZ | Disable time | DE = X, VIO < 3 V | See Figure 6-7 | 20 | 65 | ns | |
tPHZ, tPLZ | Disable time | DE = X, VIO ≥ 3 V | 50 | ns | |||
tPZH(1), tPZL(1) | Enable time | DE = VIO, VIO < 3 V | 80 | 170 | ns | ||
tPZH(1), tPZL(1) | Enable time | DE = VIO, VIO ≥ 3 V | 80 | 155 | ns | ||
tPZH(2), tPZL(2) |
Enable time | DE = 0 V | See Figure 6-8 | 6 | 14 | μs |