SLLSEV5D July 2017 – June 2019 TIOL111 , TIOL1113 , TIOL1115
PRODUCTION DATA.
TIOL111 and TIOL111x IO-Link transceivers can be used in slave devices communicating with an IO-Link master, or as standard digital outputs to either sense or drive a wide range of sensors and loads. Table 9 shows recommended components for a typical system design.
PARAMETERS | VALUE |
---|---|
Input voltage range (L+) | 24 V, 30 V (max) |
Output current (CQ) | 200 mA |
Output voltage (VCC_OUT), Pick TIOL1115 | 5 V |
Maximum LDO output current (IVCC(OUT)) | 5 mA |
Pull-up resistors for NFAULT and WAKE | 10 kΩ |
L+ decoupling capacitor | 0.1 µF / 100 V |
LDO output capacitor | 1 µF / 10 V |
ILIM_ADJ resistor (RSET) | 10 kΩ |
Maximum Ambient Temperature, TA | 105 °C |