SLOS080V september   1978  – april 2023 TL071 , TL071A , TL071B , TL071H , TL072 , TL072A , TL072B , TL072H , TL072M , TL074 , TL074A , TL074B , TL074H , TL074M

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information for Single Channel
    5. 6.5  Thermal Information for Dual Channel
    6. 6.6  Thermal Information for Quad Channel
    7. 6.7  Electrical Characteristics: TL07xH
    8. 6.8  Electrical Characteristics (DC): TL07xC, TL07xAC, TL07xBC, TL07xI, TL07xM
    9. 6.9  Electrical Characteristics (AC): TL07xC, TL07xAC, TL07xBC, TL07xI, TL07xM
    10. 6.10 Typical Characteristics: TL07xH
    11. 6.11 Typical Characteristics: All Devices Except TL07xH
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Total Harmonic Distortion
      2. 8.3.2 Slew Rate
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
    3. 9.3 Unity Gain Buffer
      1. 9.3.1 Design Requirements
      2. 9.3.2 Detailed Design Procedure
      3. 9.3.3 Application Curves
    4. 9.4 System Examples
    5. 9.5 Power Supply Recommendations
    6. 9.6 Layout
      1. 9.6.1 Layout Guidelines
      2. 9.6.2 Layout Example
  10. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 Support Resources
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  11. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Absolute Maximum Ratings

over operating ambient temperature range (unless otherwise noted) (1)
MIN MAX UNIT
Supply voltage, VS = (V+) – (V–)  All NS and PS packages; All TL07xM devices –0.3 36 V
All other devices 0 42 V
Signal input pins Common-mode voltage (3) All NS and PS packages; All TL07xM devices (V–) – 0.3 (V–) + 36 V
All other devices (V–) – 0.5 (V+) + 0.5 V
Differential voltage (3) All NS and PS packages; All TL07xM devices (4) (V–) – 0.3 (V–) + 36 V
All other devices VS + 0.2 V
Current (3) All NS and PS packages; All TL07xM devices 50 mA
All other devices –10 10 mA
Output short-circuit (2) Continuous
Operating ambient temperature, TA –55 150 °C
Junction temperature, TJ 150 °C
Case temperature for 60 seconds - FK package 260 °C
Lead temperature 1.8 mm (1/16 inch) from case for 10 seconds 300 °C
Storage temperature, Tstg –65 150 °C
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Short-circuit to ground, one amplifier per package.
Input pins are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5 V beyond the supply rails must be current limited to 10 mA or less.
Differential voltage only limited by input voltage.