SLVS610C August   2006  – October 2024

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Reference Section Electrical Characteristics
    6. 5.6  Oscillator Section Electrical Characteristics
    7. 5.7  Error-Amplifier Section Electrical Characteristics
    8. 5.8  Current-Sense Section Electrical Characteristics
    9. 5.9  Output Section Electrical Characteristics
    10. 5.10 Undervoltage-Lockout Section Electrical Characteristics
    11. 5.11 Pulse-Width Modulator Section Electrical Characteristics
    12. 5.12 Supply Voltage Electrical Characteristics
    13. 5.13 Typical Characteristics
  7. Detailed Description
    1. 6.1 Functional Block Diagram
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Shutdown Technique
    3. 7.3 Open-Loop Laboratory Test Fixture
    4. 7.4 Typical Application
      1. 7.4.1 Application Curves
  9. Device and Documentation Support
    1. 8.1 Related Links
    2. 8.2 Trademarks
    3. 8.3 Electrostatic Discharge Caution
    4. 8.4 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted) (1)(2)
MINMAXUNIT
VCCSupply voltageLow impedance source30V
ICC < 30 mASelf
limiting
VIAnalog input voltage rangeVFB and ISENSE–0.36.3V
ICCSupply current30mA
IOOutput current±1A
IO(sink)Error amplifier output sink current10mA
Output energyCapacitive load5μJ
TJVirtual junction temperature150°C
TstgStorage temperature range–65150°C
Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.