The areas under the curves represent conditions that may cause the device to oscillate. For curves B, C, and D, R2 and V
REF were adjusted to establish the initial V
KA and I
KA conditions with C
L = 0. V
BATT and C
L then were adjusted to determine the ranges of stability (see
Figure 18 and
Figure 19 for test circuits).