over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
VCC | Supply voltage(2) | | 41 | V |
VI | Amplifier input voltage | | VCC + 0.3 | V |
VO | Collector output voltage | | 41 | V |
IO | Collector output current | | 250 | mA |
| Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds | | 260 | °C |
Tstg | Storage temperature range | –65 | 150 | °C |
(1) Stresses beyond those listed under
Absolute Maximum Ratings may cause
permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated
under
Recommended Operating Conditions is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device
reliability.
(2) All voltages are with respect to the network ground terminal.