SLFS078C October 2006 – April 2024 TLC555-Q1
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
Table 6-1 lists the device functional modes. For a valid reset voltage condition, use an external pullup resistor to VDD (if using the RESET functionality), or short the RESET pin directly to VDD (if the RESET functionality is not used).
RESET | TRIGGER VOLTAGE(1) | THRESHOLD VOLTAGE(1) | OUTPUT | DISCHARGE SWITCH |
---|---|---|---|---|
Low | Irrelevant | Irrelevant | Low | On |
High | < 1/3 VDD | Irrelevant | High | Off |
High | > 1/3 VDD | > 2/3 VDD | Low | On |
High | > 1/3 VDD | < 2/3 VDD | As previously established |