SLVSEJ1A February 2021 – May 2022 TLC6983
PRODUCTION DATA
The controller sends the read command. When the first device receives this command, it inserts its 48-bit data before End_bytes, and meanwhile shifts out to the second device. When the second device receives this command, it inserts its 48-bit data before End_bytes and meanwhile shifts out to the third device. The data of all the device is shifted out from the last device SOUT with this flow. The MSB is transmitted first and the LSB transmitted last.