SLVSEJ1A February 2021 – May 2022 TLC6983
PRODUCTION DATA
The thermal shutdown (TSD) function turns off all IC constant-current outputs when the junction temperature (TJ) exceeds 170°C (typical). The TSD resumes normal operation when TJ falls below 155°C (typical).