SLLSF58B July   2020  – May 2022 TLIN1027-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 ESD Ratings - IEC
    4. 6.4 Thermal Information
    5. 6.5 Recommended Operating Conditions
    6. 6.6 Electrical Characteristics
    7. 6.7 Switching Characteristics
    8. 6.8 Timing Requirements
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  LIN (Local Interconnect Network) Bus
        1. 8.3.1.1 LIN Transmitter Characteristics
        2. 8.3.1.2 LIN Receiver Characteristics
          1. 8.3.1.2.1 Termination
      2. 8.3.2  TXD (Transmit Input and Output)
      3. 8.3.3  RXD (Receive Output)
      4. 8.3.4  VSUP (Supply Voltage)
      5. 8.3.5  GND (Ground)
      6. 8.3.6  EN (Enable Input)
      7. 8.3.7  Protection Features
      8. 8.3.8  Bus Stuck Dominant System Fault: False Wake-Up Lockout
      9. 8.3.9  Thermal Shutdown
      10. 8.3.10 Under Voltage on VSUP
      11. 8.3.11 Unpowered Device and LIN Bus
    4. 8.4 Device Functional Modes
      1. 8.4.1 Normal Mode
      2. 8.4.2 Sleep Mode
      3. 8.4.3 Standby Mode
      4. 8.4.4 Wake-Up Events
        1. 8.4.4.1 Wake-Up Request (RXD)
        2. 8.4.4.2 Mode Transitions
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedures
        1. 9.2.2.1 Normal Mode Application Note
        2. 9.2.2.2 Standby Mode Application Note
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Wake-Up Events

There are two ways to wake up from sleep mode:

  • Remote wake-up initiated by the falling edge of a recessive (high) to dominant (low) state transition on LIN bus where the dominant state is be held for tLINBUS filter time. After this tLINBUS filter time has been met and a rising edge on the LIN bus going from dominant state to recessive state initiates a remote wake-up event, eliminating false wake-ups from disturbances on the LIN bus or if the bus is shorted to ground.
  • Local wake-up through EN being set high for longer than tMODE_CHANGE.