SLLSFK7A March   2021  – April 2022 TLIN2021A-Q1

PRODMIX  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (continued)
  6. Pin Configuration and Functions
  7. Specification
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 ESD Ratings - IEC Specification
    4. 7.4 Thermal Information
    5. 7.5 Recommended Operating Conditions
    6. 7.6 Power Supply Characteristics
    7. 7.7 Electrical Characteristics
    8. 7.8 AC Switching Characteristics
    9. 7.9 Typical Curves
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  LIN
        1. 9.3.1.1 LIN Transmitter Characteristics
        2. 9.3.1.2 LIN Receiver Characteristics
          1. 9.3.1.2.1 Termination
      2. 9.3.2  TXD
      3. 9.3.3  RXD
      4. 9.3.4  VSUP
      5. 9.3.5  GND
      6. 9.3.6  EN
      7. 9.3.7  WAKE
      8. 9.3.8  INH
      9. 9.3.9  Local Faults
      10. 9.3.10 TXD Dominant Time-Out (DTO)
      11. 9.3.11 Bus Stuck Dominant System Fault: False Wake-Up Lockout
      12. 9.3.12 Thermal Shutdown
      13. 9.3.13 Under Voltage on VSUP
      14. 9.3.14 Unpowered Device
    4. 9.4 Device Functional Modes
      1. 9.4.1 Normal Mode
      2. 9.4.2 Sleep Mode
      3. 9.4.3 Standby Mode
      4. 9.4.4 Wake-Up Events
        1. 9.4.4.1 Local Wake-Up (LWU) via WAKE Input Terminal
        2. 9.4.4.2 Wake-Up Request (RXD)
  10. 10Application Information Disclaimer
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedures
        1. 10.2.2.1 Normal Mode Application Note
        2. 10.2.2.2 TXD Dominant State Time-Out Application Note
        3. 10.2.2.3 Standby Mode Application Note
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 Support Resources
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

ESD Ratings - IEC Specification

VALUE UNIT
VESD Electrostatic discharge LIN, VSUP, WAKE terminal to GND(1) IEC 62228-2 per ISO 10605
Contact discharge
R = 330 Ω, C = 150 pF (IEC 61000-4-2)
±8000 V
LIN terminal to GND(1) IEC 62228-2 per ISO 10605
Indirect contact discharge
R = 330 Ω, C = 150 pF (IEC 61000-4-2)
±8000
VTRAN Non-synchronous transient injection LIN, VSUP, WAKE terminal to GND(1) IEC 62228-2 per IEC 62215-3
12 V electrical systems
Pulse 1
-100 V
IEC 62215-3
24 V electrical systems (3)
Pulse 1
-450
IEC 62228-2 per IEC 62215-3
12 V electrical systems
24 V electrical systems (3)
Pulse 2
75
IEC 62228-2 per IEC 62215-3
12 V electrical systems
Pulse 3a
-150
IEC 62215-3
24 V electrical systems (3)
Pulse 3a
-225
IEC 62228-2 per IEC 62215-3
12 V electrical systems
Pulse 3b
150
IEC 62215-3
24 V electrical systems (3)
Pulse 3b
225
Direct capacitor coupling LIN terminal to GND(2) SAE J2962-1 per ISO 7637-3
DCC - Slow transient pulse
±30
Results given here are specific to the IEC 62228-2 Integrated circuits – EMC evaluation of transceivers – Part 2: LIN transceivers. Testing performed by OEM approved independent 3rd party, EMC report available upon request.
Results given here are specific to the SAE J2962-1 Communication Transceivers Qualification Requirements - LIN. Testing performed by OEM approved independent 3rd party, EMC report available upon request.
Verified during characterization