Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
ESD Ratings - IEC
5.4
Thermal Information
5.5
Recommended Operating Conditions
5.6
Electrical Characteristics
5.7
Switching Characteristics
5.8
Timing Requirements
6
Parameter Measurement Information
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
LIN (Local Interconnect Network) Bus
7.3.1.1
LIN Transmitter Characteristics
7.3.1.2
LIN Receiver Characteristics
7.3.1.2.1
Termination
7.3.2
TXD (Transmit Input and Output)
7.3.3
RXD (Receive Output)
7.3.4
VSUP (Supply Voltage)
7.3.5
GND (Ground)
7.3.6
EN (Enable Input)
7.3.7
Protection Features
7.3.8
TXD Dominant Time Out (DTO)
7.3.9
Bus Stuck Dominant System Fault: False Wake-Up Lockout
7.3.10
Thermal Shutdown
7.3.11
Under Voltage on VSUP
7.3.12
Unpowered Device and LIN Bus
7.4
Device Functional Modes
7.4.1
Normal Mode
7.4.2
Sleep Mode
7.4.3
Standby Mode
7.4.4
Wake-Up Events
7.4.4.1
Wake-Up Request (RXD)
7.4.4.2
Mode Transitions
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedures
8.2.2.1
Normal Mode Application Note
8.2.2.2
Standby Mode Application Note
8.2.2.2.1
TXD Dominant State Timeout Application Note
8.2.3
Application Curves
8.3
Power Supply Recommendations
8.4
Layout
8.4.1
Layout Guidelines
8.4.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Revision History
11
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
D|8
MSOI002K
DRB|8
MPDS118K
Thermal pad, mechanical data (Package|Pins)
DRB|8
QFND695C
Orderable Information
sllsey6g_oa
sllsey6g_pm
1
Features
AEC-Q100 Qualified for automotive applications
Temperature grade 1: –40°C to 125°C T
A
Device HBM certification level: ±8kV
Device CDM certification level: ±1.5kV
Compatible with LIN 2.0, LIN 2.1, LIN 2.2, LIN 2.2 A and ISO/DIS 17987–4.2 (See
SLLA490
)
Conforms to SAE J2602 recommended practice for LIN (See
SLLA490
)
Supports ISO 9141 (K-line)
Supports 12V applications
LIN transmit data rate up to 20kbps
Wide operating ranges
4V to 36V Supply voltage
±45V LIN bus fault protection
Sleep mode: ultra-low current consumption allows wake-up event from:
LIN bus
Local wake up through EN
Power up and down glitch free operation
Protection features:
Under voltage protection on V
SUP
TXD Dominant time out protection (DTO)
Thermal shutdown protection
Unpowered node or ground disconnection failsafe at system level.
Available in SOIC (8) and leadless VSON (8) packages for improved automated optical inspection (AOI) capability