over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
Supply voltage: VS = (V+) – (V–) |
|
42 |
V |
Differential Input Voltage, VID |
–42 |
42 |
V |
Input pins (IN+, IN–) from (V–)(2) |
–0.3 |
42 |
V |
Current into Input pins (IN+, IN–)(3) |
–10 |
10 |
mA |
Output (Open-drain version only) from (V–)(4) |
–0.3 |
42 |
V |
Output (OUT) (Push-Pull) from (V–) |
–0.3 |
(V+) + 0.3 |
V |
Output short circuit current(5) |
-10 |
10 |
mA |
Junction temperature, TJ |
|
150 |
°C |
Storage temperature, Tstg |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Input terminals are diode-clamped to (V–). Inputs (IN+, IN–) can be greater than (V+) and OUT as long as it is within the –0.3V to 42V range
(3) Input terminals are diode-clamped to (V–). Input signals that swing more than 0.3 V below (V–) must be current-limited to 10mA or less.
(4) Output (OUT) for open drain can be greater than (V+) and inputs (IN+, IN–) as long as it is within the –0.3V to 42V range
(5) Short-circuit to (V–) or (V+).