SBAS906 March 2018 TLV320ADC3100
PRODUCTION DATA.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
PLL ON | PLL DIV | PLL MULT R | |||||
R/W-0h | R/W-001h | R/W-0001h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | PLL ON | R/W | 0h | 0: PLL is powered down
1: PLL is powered up |
6:4 | PLL DIV | R/W | 001h | 000: PLL divider P = 8
001: PLL divider P = 1 010: PLL divider P = 2 ... 110: PLL divider P = 6 111: PLL divider P = 7 |
3:0 | PLL MULT R | R/W | 0001h | 0000: PLL multiplier R = 16
0001: PLL multiplier R = 1 0010: PLL multiplier R = 2 ... 1110: PLL multiplier R = 14 1111: PLL multiplier R = 15 |