SLVSFT6B May 2021 – January 2022 TLVM13630
PRODUCTION DATA
The recommended switching frequency for standard output voltages can be found in Table 7-1. For a 5-V output, the recommended switching frequency is 1 MHz. To set the switching frequency to 1 MHz, connect a 13.0-kΩ resistor between the RT pin and AGND.