SBAS934A June 2020 – December 2021 TMAG5170-Q1
PRODUCTION DATA
The TMAG5170-Q1 offers multiple update rates for system design flexibility. Figure 7-4 shows the different update rates for the TMAG5170-Q1 during continuous conversion.
OPERATING MODE | REGISTER SETTING | UPDATE RATE | COMMENT | ||
---|---|---|---|---|---|
SINGLE AXIS | TWO AXIS | THREE AXIS | |||
X, Y, Z Axis | CONV_AVG = 000b | 20 kSPS | 13.3 kSPS | 10 kSPS | Fastest update rate |
X, Y, Z Axis | CONV_AVG = 001b | 13.3 kSPS | 8.0 kSPS | 5.7 kSPS | |
X, Y, Z Axis | CONV_AVG = 010b | 8.0 kSPS | 4.4 kSPS | 3.1 kSPS | |
X, Y, Z Axis | CONV_AVG = 011b | 4.4 kSPS | 2.4 kSPS | 1.6 kSPS | |
X, Y, Z Axis | CONV_AVG = 100b | 2.4 kSPS | 1.2 kSPS | 0.8 kSPS | |
X, Y, Z Axis | CONV_AVG = 101b | 1.2 kSPS | 0.6 kSPS | 0.4 kSPS | Best SNR case |