SLYS045B June   2021  – July 2024 TMAG5273

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Electrical Characteristics
    6. 5.6  Temperature Sensor
    7. 5.7  Magnetic Characteristics For A1, B1, C1, D1
    8. 5.8  Magnetic Characteristics For A2, B2, C2, D2
    9. 5.9  Magnetic Temp Compensation Characteristics
    10. 5.10 I2C Interface Timing
    11. 5.11 Power up & Conversion Time
    12. 5.12 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Magnetic Flux Direction
      2. 6.3.2 Sensor Location
      3. 6.3.3 Interrupt Function
      4. 6.3.4 Device I2C Address
      5. 6.3.5 Magnetic Range Selection
      6. 6.3.6 Update Rate Settings
    4. 6.4 Device Functional Modes
      1. 6.4.1 Standby (Trigger) Mode
      2. 6.4.2 Sleep Mode
      3. 6.4.3 Wake-up and Sleep (W&S) Mode
      4. 6.4.4 Continuous Measure Mode
    5. 6.5 Programming
      1. 6.5.1 I2C Interface
        1. 6.5.1.1 SCL
        2. 6.5.1.2 SDA
        3. 6.5.1.3 I2C Read/Write
          1. 6.5.1.3.1 Standard I2C Write
          2. 6.5.1.3.2 General Call Write
          3. 6.5.1.3.3 Standard 3-Byte I2C Read
          4. 6.5.1.3.4 1-Byte I2C Read Command for 16-Bit Data
          5. 6.5.1.3.5 1-Byte I2C Read Command for 8-Bit Data
          6. 6.5.1.3.6 I2C Read CRC
      2. 6.5.2 Data Definition
        1. 6.5.2.1 Magnetic Sensor Data
        2. 6.5.2.2 Temperature Sensor Data
        3. 6.5.2.3 Angle and Magnitude Data Definition
        4. 6.5.2.4 Magnetic Sensor Offset Correction
  8. Application and Implementation
    1. 7.1 Application Information
      1. 7.1.1 Select the Sensitivity Option
      2. 7.1.2 Temperature Compensation for Magnets
      3. 7.1.3 Sensor Conversion
        1. 7.1.3.1 Continuous Conversion
        2. 7.1.3.2 Trigger Conversion
        3. 7.1.3.3 Pseudo-Simultaneous Sampling
      4. 7.1.4 Magnetic Limit Check
      5. 7.1.5 Error Calculation During Linear Measurement
      6. 7.1.6 Error Calculation During Angular Measurement
    2. 7.2 Typical Application
      1. 7.2.1 Magnetic Tamper Detection
        1. 7.2.1.1 Design Requirements
        2. 7.2.1.2 Detailed Design Procedure
        3. 7.2.1.3 Application Curves
      2. 7.2.2 I2C Address Expansion
        1. 7.2.2.1 Design Requirements
        2. 7.2.2.2 Detailed Design Procedure
      3. 7.2.3 Angle Measurement
        1. 7.2.3.1 Design Requirements
        2. 7.2.3.2 Detailed Design Procedure
          1. 7.2.3.2.1 Gain Adjustment for Angle Measurement
        3. 7.2.3.3 Application Curves
    3. 7.3 Best Design Practices
    4. 7.4 Power Supply Recommendations
    5. 7.5 Layout
      1. 7.5.1 Layout Guidelines
      2. 7.5.2 Layout Example
  9. Register Maps
    1. 8.1 TMAG5273 Registers
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DBV|6
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Magnetic Characteristics For A1, B1, C1, D1

over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
BIN Linear magnetic range for X, Y, and Z _RANGE = 0b ±40 mT
_RANGE = 1b ±80 mT
SENS Sensitivity, X, Y, or Z axis _RANGE = 0b, ±40mT 820 LSB/mT
_RANGE = 1b, ±80mT 410 LSB/mT
SENSER Sensitivity error, X, Y, Z axis TA = 25°C ±5.0% ±20.0%
SENSER_DR Sensitivity error drift from 25°C
X, Y, Z axis
±5.0%
SENSLER Sensitivity linearity error
TA = 25°C
X, Y Axis ±0.10%
Z Axis ±0.10%
SENSMS Sensitivity mismatch
TA = 25°C
X-Y axes ±0.50%
Y-Z, or X-Z axes ±1.0%
SENSMS_DR Sensitivity mismatch drift X-Y axes ±5%
Y-Z, or X-Z axes
±15%
 
Boff Offset TA = 25°C ±300 ±1000 µT
Boff_TC Offset drift ±3.0 ±10.0 µT/°C
NRMS RMS (1 Sigma) magnetic noise
CONV_AVG = 000b
TA = 25°C
LP_LN = 0b
X, Y Axis
125 µT
LP_LN = 1b
X, Y Axis
110 µT
RMS (1 Sigma) magnetic noise
CONV_AVG = 101b
TA = 25°C
LP_LN = 0b
X, Y Axis
22 µT
LP_LN = 1b
X, Y Axis
22 µT
RMS (1 Sigma) magnetic noise
CONV_AVG = 000b
TA = 25°C
LP_LN = 0b
Z Axis
68 µT
LP_LN = 1b
Z Axis
66 µT
RMS (1 Sigma) magnetic noise
CONV_AVG = 101b
TA = 25°C
LP_LN = 0b
Z Axis
11 µT
LP_LN = 1b
Z Axis
9 µT
AERR Angle error
CONV_AVG = 101b
TA = 25°C
Y-Z ±1.0 Degree
X-Z ±1.0 Degree
X-Y ±0.5 Degree