SLOS887F
September 2014 – June 2022
TMP112-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Description (continued)
6
Pin Configuration and Functions
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Electrical Characteristics
7.6
Specifications for User-Calibrated Systems
7.7
Timing Requirements
7.8
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Digital Temperature Output
8.3.2
Serial Interface
8.3.2.1
Bus Overview
8.3.2.2
Serial Bus Address
8.3.2.3
Writing and Reading Operation
8.3.2.4
Target Mode Operation
8.3.2.4.1
Target Receiver Mode
8.3.2.4.2
Target Transmitter Mode
8.3.2.5
SMBus Alert Function
8.3.2.6
General Call
8.3.2.7
High-Speed (Hs) Mode
8.3.2.8
Timeout Function
8.3.2.9
Timing Diagrams
8.3.2.9.1
Two-Wire Timing Diagrams
8.4
Device Functional Modes
8.4.1
Continuous-Conversion Mode
8.4.2
Extended Mode (EM)
8.4.3
Shutdown Mode (SD)
8.4.4
One-Shot and Conversion Ready Mode (OS)
8.4.5
Thermostat Mode (TM)
8.4.5.1
Comparator Mode (TM = 0)
8.4.5.2
Interrupt Mode (TM = 1)
8.5
Programming
8.5.1
Pointer Register
8.5.2
Temperature Register
8.5.3
Configuration Register
8.5.3.1
Shutdown Mode (SD)
8.5.3.2
Thermostat Mode (TM)
8.5.3.3
Polarity (POL)
8.5.3.4
Fault Queue (F1/F0)
8.5.3.5
Converter Resolution (R1 and R0)
8.5.3.6
One-Shot (OS)
8.5.3.7
Extended Mode (EM)
8.5.3.8
Alert (AL)
8.5.3.9
Conversion Rate (CR)
8.5.4
High- and Low-Limit Registers
9
Application and Implementation
9.1
Application Information
9.1.1
Calibrating for Improved Accuracy
9.1.1.1
Example 1: Finding Worst-Case Accuracy From –15°C to 50°C
9.1.1.2
Example 2: Finding Worst-Case Accuracy From 25°C to 100°C
9.1.2
Using The Slope Specifications With a 1-Point Calibration
9.1.2.1
Power Supply-Level Contribution to Accuracy
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.3
Application Curve
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Documentation Support
12.1.1
Related Documentation
12.2
Receiving Notification of Documentation Updates
12.3
Community Resources
12.4
Trademarks
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DRL|6
MPDS159H
Thermal pad, mechanical data (Package|Pins)
Orderable Information
slos887f_oa
slos887f_pm
7.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per AEC Q100-002
(1)
±2000
V
Charged device model (CDM), per AEC Q100-011
±1000
(1)
AEC Q100-002 indicates HBM stressing is done in accordance with the ANSI/ESDA/JEDEC JS-001 specification.