SNIS209C July 2021 – June 2022 TMP126
PRODUCTION DATA
Bit 8 of the command word is the read/write bit.
Setting this bit to 1 will issue a read command. During a read command the TMP126 will control the SIO pin after the command word. Setting this bit to 0 will issue a write command. During a write command the controller will control the SIO pin and the TMP126 will internally set the SIO pin to high impedance.