SBOSA50A
December 2021 – March 2022
TMP127-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Device Comparison
6
Pin Configuration and Functions
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Electrical Characteristics
7.6
SPI Interface Timing
7.7
Timing Diagrams
7.8
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Low Power Consumption
8.4
Device Functional Modes
8.4.1
Continuous Conversion Mode
8.4.2
Shutdown Mode
8.5
Programming
8.5.1
Temperature Data Format
8.5.2
Serial Bus Interface
8.5.2.1
Communication in Shutdown Mode
8.5.2.2
Communication in Continuous Conversion Mode
8.5.2.3
Internal Register Structure
9
Application and Implementation
9.1
Application Information
9.2
Typical Applications
9.2.1
Read-Only Configuration
9.2.1.1
Design Requirements
9.2.1.2
Detailed Design Procedure
9.2.2
Read/Write Configuration
9.2.2.1
Design Requirements
9.2.2.2
Detailed Design Procedure
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Receiving Notification of Documentation Updates
12.2
Support Resources
12.3
Trademarks
12.4
Electrostatic Discharge Caution
12.5
Glossary
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DBV|6
MPDS026Q
Thermal pad, mechanical data (Package|Pins)
Orderable Information
sbosa50a_oa
sbosa50a_pm
7.3
Recommended Operating Conditions
MIN
NOM
MAX
UNIT
V
DD
Supply voltage
1.62
3.3
5.5
V
V
I/O
SIO
0
V
DD
V
V
I/O
CS
, SCLK
0
5.5
V
T
A
Operating ambient temperature
(1)
-55
175
°C
(1)
HTOL was performed at 175 °C for 1410 hours