SPNS254A June 2022 – March 2024 TMS570LC4357-SEP
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
TERMINAL | SIGNAL TYPE | DEFAULT PULL STATE | PULL TYPE | OUTPUT BUFFER DRIVE STRENGTH | DESCRIPTION | |
---|---|---|---|---|---|---|
SIGNAL NAME | 337 GWT | |||||
AD1EVT/MII_RX_ER/RMII_RX_ER/nTZ1_1 | N19 | I/O | Pulldown | Programmable, 20 µA | 2-mA ZD | ADC1 event trigger input, or GIO |
AD1IN[0] | W14 | Input | - | - | - | ADC1 Input |
AD1IN[1] | V17 | Input | - | - | - | ADC1 Input |
AD1IN[2] | V18 | Input | - | - | - | ADC1 Input |
AD1IN[3] | T17 | Input | - | - | - | ADC1 Input |
AD1IN[4] | U18 | Input | - | - | - | ADC1 Input |
AD1IN[5] | R17 | Input | - | - | - | ADC1 Input |
AD1IN[6] | T19 | Input | - | - | - | ADC1 Input |
AD1IN[7] | V14 | Input | - | - | - | ADC1 Input |
AD1IN[8]/AD2IN[8] | P18 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[9]/AD2IN[9] | W17 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[10]/AD2IN[10] | U17 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[11]/AD2IN[11] | U19 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[12]/AD2IN[12] | T16 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[13]/AD2IN[13] | T18 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[14]/AD2IN[14] | R18 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[15]/AD2IN[15] | P19 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[16]/AD2IN[0] | V13 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[17]/AD2IN[1] | U13 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[18]/AD2IN[2] | U14 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[19]/AD2IN[3] | U16 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[20]/AD2IN[4] | U15 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[21]/AD2IN[5] | T15 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[22]/AD2IN[6] | R19 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[23]/AD2IN[7] | R16 | Input | - | - | - | ADC1/ADC2 shared Input |
AD1IN[24] | N18 | Input | - | - | - | ADC1 Input |
AD1IN[25] | P17 | Input | - | - | - | ADC1 Input |
AD1IN[26] | P16 | Input | - | - | - | ADC1 Input |
AD1IN[27] | P15 | Input | - | - | - | ADC1 Input |
AD1IN[28] | R15 | Input | - | - | - | ADC1 Input |
AD1IN[29] | R14 | Input | - | - | - | ADC1 Input |
AD1IN[30] | T14 | Input | - | - | - | ADC1 Input |
AD1IN[31] | T13 | Input | - | - | - | ADC1 Input(1) |
AD2EVT | T10 | I/O | Pulldown | Programmable, 20 µA | 2-mA ZD | ADC2 event trigger input, or GIO |
MIBSPI3NCS[0]/AD2EVT/eQEP1I | V10(2) | |||||
AD2IN[16] | W13 | Input | - | - | - | ADC2 Input |
AD2IN[17] | W12 | Input | - | - | - | ADC2 Input |
AD2IN[18] | V12 | Input | - | - | - | ADC2 Input |
AD2IN[19] | U12 | Input | - | - | - | ADC2 Input |
AD2IN[20] | T11 | Input | - | - | - | ADC2 Input |
AD2IN[21] | U11 | Input | - | - | - | ADC2 Input |
AD2IN[22] | V11 | Input | - | - | - | ADC2 Input |
AD2IN[23] | W11 | Input | - | - | - | ADC2 Input |
AD2IN[24] | V19 | Input | - | - | - | ADC2 Input |
AD2IN[24] | W18 | |||||
ADREFHI | V15(3) | Input | - | - | - | ADC high reference supply |
ADREFLO | V16(3) | Input | - | - | - | ADC low reference supply |
MIBSPI3SOMI/AD1EXT_ENA/ECAP2 | V8 | Output | Pullup | 20 µA | 2-mA ZD | External Mux ENA |
MIBSPI5SOMI[3]/DMM_DATA[15]/I2C2_SCL/AD1EXT_ENA | G16 | |||||
MIBSPI3SIMO/AD1EXT_SEL[0]/ECAP3 | W8 | Output | Pullup | 20 µA | 2-mA ZD | External Mux Select 0 |
MIBSPI5SIMO[1]/DMM_DATA[9]/AD1EXT_SEL[0] | E16 | |||||
MIBSPI3CLK/AD1EXT_SEL[1]/eQEP1A | V9 | Output | Pullup | 20 µA | 2-mA ZD | External Mux Select 1 |
MIBSPI5SIMO[2]/DMM_DATA[10]/AD1EXT_SEL[1] | H17 | |||||
MIBSPI5SIMO[3]/DMM_DATA[11]/I2C2_SDA/AD1EXT_SEL[2] | G17 | Output | Pullup | 20 µA | 2-mA ZD | External Mux Select 2 |
MIBSPI5SOMI[1]/DMM_DATA[13]/AD1EXT_SEL[3] | E17 | Output | Pullup | 20 µA | 2-mA ZD | External Mux Select 3 |
MIBSPI5SOMI[2]/DMM_DATA[14]/AD1EXT_SEL[4] | H16 | Output | Pullup | 20 µA | 2-mA ZD | External Mux Select 4 |
VCCAD | W15(3) | Input | - | - | - | Operating supply for ADC |
VSSAD | W16(3) | Input | - | - | - | ADC supply ground |
VSSAD | W19(3) | Input | - | - | - | ADC supply ground |