SCDS466 august   2023 TMUX7612

ADVANCE INFORMATION  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Thermal Information
    4. 6.4  Recommended Operating Conditions
    5. 6.5  Source or Drain Continuous Current Switch Pairs
    6. 6.6  Source or Drain Pulsed Current
    7. 6.7  Electrical Characteristics (12 V Single Supply)
    8. 6.8  Switching Characteristics (12 V Single Supply)
    9. 6.9  Electrical Characteristics (±15 V Dual Supply)
    10. 6.10 Switching Characteristics (±15 V Dual Supply)
    11. 6.11 Electrical Characteristics (±20 V Dual Supply)
    12. 6.12 Switching Characteristics (±20 V Dual Supply)
    13. 6.13 Electrical Characteristics (+37.5 V/–12.5 V Dual Supply)
    14. 6.14 Switching Characteristics (+37.5 V/–12.5 V Dual Supply)
    15. 6.15 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Bidirectional Operation
      2. 7.3.2 Rail-to-Rail Operation
      3. 7.3.3 1.8 V Logic Compatible Inputs
      4. 7.3.4 Flat On-Resistance
      5. 7.3.5 Power-Up Sequence Free
      6. 7.3.6 Ultra-Low Charge Injection
      7. 7.3.7 Ultra-Low Leakage Current
    4. 7.4 Device Functional Modes
      1. 7.4.1 Truth Tables
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Detailed Design Procedure
      2. 8.2.2 Design Requirements
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Mechanical, Packaging, and Orderable Information
    1. 10.1 Tape and Reel Information
    2. 10.2 Mechanical Data

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Ultra-Low Leakage Current

The TMUX7612 provides extremely low on-leakage and off-leakage currents. This device is capable of switching signals from high source-impedance inputs into a high input-impedance op amp with minimal offset error because of the ultra-low leakage currents. Figure 7-2 shows typical leakage currents of the TMUX7612 devices versus source or drain voltage at VDD = 32.5 V, VSS = -12.5 V and 50°C. The typical performance seen here is less than 0.2 nA at 50°C, which enables the TMUX7612 to be used in a wide array of precision applications.

GUID-20230606-SS0I-FJCD-K44W-GJS251F6QL1T-low.svg
VDD = 37.5 V, VSS = -12.5 V
Figure 7-2 Leakage Current at 50°C vs Bias Voltage