SLASEP6B September 2019 – December 2020 TPA6304-Q1
PRODUCTION DATA
When Thermal Gain Foldback is enabled and if it has reduced the gain below 0 dB due to high temperature, the device creates a thermal gain foldback warning event. Once the temperature decreases and the gain foldback circuitry releases the gain back up to 0 dB, this warning is cleared. Current status is reported in Temperature (OTW) and Thermal Gain Foldback Warning Status Register and latched events are reported in Temperature (OTW) and Thermal Gain Foldback Warning Memory Register.