SLVSE16C May 2019 – January 2020 TPS1HB08-Q1
PRODUCTION DATA.
In this application, the TPS1HB08-Q1 must allow for the maximum DC current with margin but minimize the energy in the switch during a fault condition by minimizing the current limit. For this application, the best ILIM set point is approximately 12 A. Equation 7 allows you to calculate the RILIM value that is placed from the ILIM pins to VBB. RILIM is calculated in kΩ.
Because this device is version A, the KCL value in the Specifications section is 160 A × kΩ.
For a ILIM of 12 A, the RILIM value should be set at around 13.3 kΩ